Beech TRU Dempsey 14562A Home

Perfect home for the couple just getting started, or anyone wanting to downsize!

Pricing

Base: $25,200
* Includes delivery in Ohio

Size

14 x 60

View Video Tour

General

  • HUD Code
  • 20 lb. Roof Load Std., 30 psf optional
  • Thermal Zone 1 Std., zones 2 and 3 optional
  • Wind Zone 1 Std., zones 2 and 3 optional

Frame

  • I Beam: 12” or 10” model specific
  • Outriggers: 96” spacing, recessed 10” (approx)
  • Crossmembers: 96” spacing
  • Header (Front/Rear): Flush, not recessed
  • Axles: Spread (no equalizers) overslung mounted.
  • Brake Axles: One, except where more are mandatory by state DOT
  • Hitch Beam: Fixed Hitch, not detachable, 8” Optional: Detachable ($50)
  • Hitch: Detachable

Floor

  • Joists: 2x6 / 19.2” O.C.
  • Carpet: Factory Select
  • Pad: 3.5 lb. (minimum) Rebond Pad
  • Vinyl: Factory Select
  • Decking: 19/32” 4x8 OSB T&G

Exterior (7’0” Sidewalls)

  • Vinyl Siding: Standard
  • Sheathing: WZ 1 Foam standard, plant specific brand. WZ 2 & 3 Includes OSB
  • House Wrap Over OSB (where used)
  • Shutters: None

Windows & Doors

  • Front door: Out swing 34” x 76” blank, no storm
  • Rear door: Out swing 32” x 76” blank, no storm
  • Interior doors: Factory Select
  • Windows: Metal single glaze, size per prints.
  • Metal/mil finish storm windows for thermal zone 2 and 3 only

Roof / Ceiling

  • Design Load: 20 psf Live load standard, 30 psf options where needed
  • Shingles: 20 year
  • Trusses: 24” O.C. spacing
  • Sheathing: 7/16” OSB
  • Insulation: Blown Fiberglass
  • Ceiling: Textured
  • Ceiling Slope: Vault/Flat Ceiling
  • Attic Ventilation Pot vents (low), Ridge vent high

Plumbing

  • Water Heater: 30 gallon electric
  • Kitchen Sink: Stainless Steel, dbl bowl
  • Lavatory Sinks: Plastic
  • Faucets: Plastic
  • Master Bath: 54” ABS Plastic Tub
  • Hall Bath: 54” ABS Plastic Tub
  • Tub One-piece surround

HVAC

  • Heat: 10 KW Electric Furnace (gas optional)
  • Ductwork: Metal duct
  • Thermostat: 8 Wire

Electrical

  • Load Center: 200 amp
  • (100 amp allowed when gas option ordered – gas range and gas furnace).
  • Exterior Receptacles and Switches: (1) GFI recept and cover.
  • Interior Receptacles and Switches: white, self contained
  • Phone Jack(s): None
  • AC: Conduit

Walls

  • Exterior Wall Construction: 2x4, 16” O.C. spacing
  • Exterior Wall Height Sidewall = 7’0”
  • Interior Wall Construction: 2x3 studs 24 O.C.
  • Marriage Wall: 2x3 Studs spaced 24” O.C.
  • Wall Coverings: 5/16” minimum VOG or paper on gyp
  • Wall Coverage at Closets: 5/16” gyp, raw

Interior Features

  • Cabinets: MDF / 24” tall overheads
  • Countertops (All): Formica
  • Backsplash: None
  • Closet Shelving: Closet Maid – vinyl wrapped metal.
  • Refrigerator: 18 CF
  • Range: Electric, Gas optional
  • Range Hood: 30”, 100 cfm min, vent through sidewall.
  • Valance on LR windows. No mini blinds.

Thermal (Insulation and Window Specs)

  • Zone I (standard) Windows: Metal (mil finish), single pane (no storm),
  • Floor: R11 Wall: R11 Roof: R11
  • Zone II (optional) Windows: Metal (mil finish) single pane w/ storm,
  • Floor: R11 Wall: R11 Roof: R14
  • Zone III (optional) Windows: Metal (mil finish) single pane w/ storm,
  • Floor: R22 Wall: R11 Roof: R28